AC Power Supply 12V/2A - Europe
Switching wall mount power supply. Output voltage 12V, Output current 2A, Power 24W, Wide range input 90-264V, Plug W2E for use in Europe. Output Connector 2.1x5.5, Cable length 1.8 m.
GENERAL | |
Voltage DC | 12V |
Loading | 0 to 2A |
Tolerance | ±5% |
OCP | 3.5 to 5.5A |
OVP max | 16V |
Efficiency | >82% |
Max. Power | 24W |
Ripple & Noise | 120mV p-p |
Connector UL Approved | 2.1 x 5.5 x 11mm |
INPUT | |
Voltage | 90 to 264 VAC |
Frequency | 47 to 63 Hz |
Current | 1A rms@ AC low line input and DC output full load |
Inrush Surge Current (cold start) | 40/60A max. @ power supply cold start, ambient temperature 25°C @115Vac/230Vac nominal AC input. |
Leakage current | <0.25 mA @ 240VAC input |
PROTECTION | |
Over load OCP | Fold back |
Over Voltage OVP | Voltage limiting |
Short Circuit | Yes, Output to Ground, Auto recovery when fault has been removed. Short Current & Over Current can not exceed 8A max. after 1 minute at nominal line input. |
Protection class | II |
No Load Operation | Yes, to protect the power supply and system from damage |
OTHERS | |
Dielectric Strength | HI-POT B / I/P-O/P (FG): 3KVAC / 10mA / 1 minute |
Set up time | 3000 ms max. @ AC low line Input & Output full load |
Hold-up Time | 10ms @ AC nominal Input and Output full load |
MTBF Qualification | 500,000 Calculated Hours at 25°C, by Telcordia SR-332 |
DC cable & connector | Standard length of the cable 1,8m |
Efficiency (Normal) | >77.6% min. @ 240VAC input & Full load |
Efficiency level | V |
Power Consumption | Max. 0.3W @ AC nominal Input and Output min. load – ERP IV. / ERP V has <0.3W |
Input Fuse | 1A protected against power line surges and any abnormal conditions |
OPERATING CONDITIONS | |
Temperature | 0 to 40°C |
Humidity | 8 to 90% RH non condensing |
SAFETY | |
Standards | CE | GS | CB | cULus | FCC | CCC | KC | SAA | RCM |
CE-EMC | 2014/30/EU |
CE-LVD | 2014/35/EU; EN 60950-1:2006+A11+A1+A12+A2 |
Size and Weight | |
Shipping Weight | 75 x 34 x 43mm / 160g |