AC-RE2

AC Power Supply for Radio Explorer II

Desktop power supply. Output voltage 12V, Output current 4.17A, Power 50W, Wide range input 90-264V, Output connector RE2-XLR, cable length 1.4m. Suitable power cord IEC 320 C13 „PC cable“.
GENERAL
Voltage DC12V
Loading0 to 4.17A
Tolerance±5%
OCP5.2 to 9.0A
OVP max16V
Efficiency>87%
Max. Power50W
Ripple & Noise200mV p-p
Connector UL Approved2.1 x 5.5 x 11mm
INPUT
Voltage90 to 264 VAC
Frequency47 to 63 Hz
Current1.5A rms@ AC low line input and DC output full load
Inrush Surge Current (cold start)40/60A max. @ power supply cold start, ambient temperature 25°C @115Vac/230Vac nominal AC input.
Leakage current<0.25mA max
PROTECTION
Over Current/Short protectionThe power supply will self-protect any output to ground, and auto recovery when abnormal circuit faults remove. An output short circuit is defined as any output impedance of less than 0.1 ohms. OCP method: Fold back
Over Voltage OVPVoltage limiting
Input protectionF1:T3.15AL/250V Fuse
No load protectionThe power supply is provided with no load operation to prevent the power supply and system from damage
Protection classI
OTHERS
Dielectric Strength (Hi-pot)Primary to Secondary: 3000VAC / 10mA / 60s
M.T.B.F500,000 Calculated Hours at 25°C, by Telcordia SR-332
Cable length1185#16*1C / 4ft (1,2m) round cable
PLD (power line disturbance )LINE POWER SURGE | LINE VOLTAGE SAG
Cooling methodBy natural air
Housing materialPC or PPO
Temperature coefficient<±0.5%/°C
OPERATING CONDITIONS
Temperature0 to 40°C
Humidity8 to 90% RH non condensing
SAFETY
StandardsCE | TUV/GS | CB | cULus | FCC| | VCCI | PSE | EAC | S-Mark | RCM
EMC - EMIEN 55022 Class B (2006)+ A1(2007)
EN 61000-3-2 (2006) + A1(2009) + A2 Class A(2009)/EN 61000-3-3 (2008)
EMC - EMSEN55024(1998)+A1(2001)+A2(2003) | IEC 61000-4-2 (2008) | IEC 61000-4-3 (2006) + A1(2007) + A2(2010)
IEC 61000-4-4 (2004) + A1(2010) |IEC 61000-4-5 (2005) | IEC 61000-4-6 (2008) | IEC 61000-4-8 (2009) | IEC 61000-4-11 (2004)
Size and Weight
Shipping Weight (W;H;D)430 x 250 x 480mm / 300g